{"product_id":"microtech-gefell-um930-full-bronze-214163","title":"UM930 Full Bronze","description":"\u003ch3\u003eA large diaphragm condenser designed for studio and broadcast versatility\u003c\/h3\u003e \u003cbr \/\u003eDesigned to meet the demands of sound engineers in studio and broadcast environments, the UM 930 follows the tradition of versatile high-end microphones. Its dual capsule and precision polar pattern selection make it a reliable tool to cover a wide range of applications with a consistent sonic signature. \u003cbr \/\u003e\u003cbr \/\u003e\u003ch3\u003eWho is it for and what are its uses?\u003c\/h3\u003e \u003cbr \/\u003eIdeal for singers, voice-over actors, and demanding podcasters, it also excels in instrument recording: guitars, keyboards, percussion, winds, and strings. In both broadcast and music recording, its polar patterns allow adaptation to the room, control of bleed, and optimization of the direct-to-ambient ratio. \u003cbr \/\u003e\u003cbr \/\u003e\u003ch3\u003eKey features and innovations\u003c\/h3\u003e \u003cbr \/\u003e\u003cbr \/\u003e\u003ch4\u003eMultiple polar patterns, silent switching\u003c\/h4\u003e \u003cbr \/\u003eFive polar patterns provide the flexibility needed to shape the sound at the source. Maintenance-free Reed relays ensure reliable switching, while a function mutes the signal during pattern changes to avoid any unwanted noise. The LED under the grille clearly indicates ready-to-use status. \u003cbr \/\u003e\u003cbr \/\u003e\u003ch4\u003eAnti-resonance mechanical design\u003c\/h4\u003e \u003cbr \/\u003eThe robust construction limits body resonances and mechanical vibrations. The integrated elastic suspension adjusts +\/-135 degrees for precise positioning, and interchangeable colored rings (green, red, blue) facilitate identification on set. \u003cbr \/\u003e\u003cbr \/\u003e\u003ch4\u003e\"UM 930 Twin\" version for comparison and remixing\u003c\/h4\u003e \u003cbr \/\u003eThe UM 930 Twin variant combines two microphones: one with a fixed cardioid and the other offering five simultaneous polar patterns. Signals are available via a 5-pin XLR, with the option to use an adapter to two 3-pin XLRs. This architecture allows real-time comparison to a cardioid reference and adjustment of the polar pattern during mixing.\n\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cstyle\u003e@media(max-width:632px){table[data-wb-spec]{display:grid;grid-template-columns:minmax(0,1fr) minmax(0,1fr)}table[data-wb-spec] colgroup{display:none}table[data-wb-spec] tbody,table[data-wb-spec] tr{display:contents}table[data-wb-spec] td{display:block;overflow-wrap:anywhere;grid-row:var(--wb-l);background-color:var(--wb-lb)}table[data-wb-spec] td[data-r]{grid-row:var(--wb-r);background-color:var(--wb-rb)}table[data-wb-spec] td[colspan=\"2\"]{grid-column:1\/-1}table[data-wb-spec] td:empty{display:none}}\u003c\/style\u003e\n\u003ctable data-wb-spec style=\"width:100%;table-layout:fixed\"\u003e\n\u003ccolgroup\u003e\u003ccol style=\"width:25%\"\u003e\u003ccol style=\"width:25%\"\u003e\u003ccol style=\"width:25%\"\u003e\u003ccol style=\"width:25%\"\u003e\u003c\/colgroup\u003e\n  \u003ctr style=\"background-color:var(--wb-neutral-50);--wb-l:1;--wb-r:4;--wb-lb:var(--wb-neutral-50);--wb-rb:transparent\"\u003e\u003ctd style=\"text-align:left\"\u003e\u003cstrong\u003eFrequency response\u003c\/strong\u003e\u003c\/td\u003e\u003ctd style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003e40 Hz - 18 kHz\u003c\/td\u003e\u003ctd data-r style=\"text-align:left\"\u003e\u003cstrong\u003eCapsule\u003c\/strong\u003e\u003c\/td\u003e\u003ctd data-r style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003eLarge Diaphragm\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr style=\"background-color:transparent;--wb-l:2;--wb-r:5;--wb-lb:transparent;--wb-rb:var(--wb-neutral-50)\"\u003e\u003ctd style=\"text-align:left\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\u003ctd style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003estudio microphone\u003c\/td\u003e\u003ctd data-r style=\"text-align:left\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\u003ctd data-r style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003eXLR\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr style=\"background-color:var(--wb-neutral-50);--wb-l:3;--wb-r:6;--wb-lb:var(--wb-neutral-50);--wb-rb:transparent\"\u003e\u003ctd style=\"text-align:left\"\u003e\u003cstrong\u003eDirectivity\u003c\/strong\u003e\u003c\/td\u003e\u003ctd style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003eomnidirectional\u003c\/td\u003e\u003ctd data-r style=\"text-align:left\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\u003ctd data-r style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003eGrey\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ctable data-wb-spec style=\"width:100%;table-layout:fixed\"\u003e\n\u003ccolgroup\u003e\u003ccol style=\"width:25%\"\u003e\u003ccol style=\"width:25%\"\u003e\u003ccol style=\"width:25%\"\u003e\u003ccol style=\"width:25%\"\u003e\u003c\/colgroup\u003e\n  \u003ctr style=\"background-color:transparent;--wb-l:1;--wb-r:8;--wb-lb:var(--wb-neutral-50);--wb-rb:transparent\"\u003e\u003ctd style=\"text-align:left\"\u003e\u003cstrong\u003ePolar patterns\u003c\/strong\u003e\u003c\/td\u003e\u003ctd style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003eomnidirectional, wide cardioid, cardioid, hypercardioid, figure-8\u003c\/td\u003e\u003ctd data-r style=\"text-align:left\"\u003e\u003cstrong\u003eDynamic range\u003c\/strong\u003e\u003c\/td\u003e\u003ctd data-r style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003e135 dB\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr style=\"background-color:var(--wb-neutral-50);--wb-l:2;--wb-r:9;--wb-lb:transparent;--wb-rb:var(--wb-neutral-50)\"\u003e\u003ctd style=\"text-align:left\"\u003e\u003cstrong\u003eAcoustic operating principle\u003c\/strong\u003e\u003c\/td\u003e\u003ctd style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003epressure gradient transducer\u003c\/td\u003e\u003ctd data-r style=\"text-align:left\"\u003e\u003cstrong\u003eCurrent consumption (P 48, DIN 45596, IEC 268-15)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd data-r style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003e4.5 mA\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr style=\"background-color:transparent;--wb-l:3;--wb-r:10;--wb-lb:var(--wb-neutral-50);--wb-rb:transparent\"\u003e\u003ctd style=\"text-align:left\"\u003e\u003cstrong\u003eDual capsule\u003c\/strong\u003e\u003c\/td\u003e\u003ctd style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003elarge diaphragm\u003c\/td\u003e\u003ctd data-r style=\"text-align:left\"\u003e\u003cstrong\u003eUM930 output connector\u003c\/strong\u003e\u003c\/td\u003e\u003ctd data-r style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003e3-pin XLR with gold-plated contacts\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr style=\"background-color:var(--wb-neutral-50);--wb-l:4;--wb-r:11;--wb-lb:transparent;--wb-rb:var(--wb-neutral-50)\"\u003e\u003ctd style=\"text-align:left\"\u003e\u003cstrong\u003eSensitivity at 1 kHz (cardioid)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003e20 mV\/Pa\u003c\/td\u003e\u003ctd data-r style=\"text-align:left\"\u003e\u003cstrong\u003eUM930 Twin output connector\u003c\/strong\u003e\u003c\/td\u003e\u003ctd data-r style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003e5-pin XLR with gold-plated contacts\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr style=\"background-color:transparent;--wb-l:5;--wb-r:12;--wb-lb:var(--wb-neutral-50);--wb-rb:transparent\"\u003e\u003ctd style=\"text-align:left\"\u003e\u003cstrong\u003eEquivalent noise level (cardioid)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003eCCIR 468-4 13 dB, DIN EN 60 651 7 dB - A-weighted measurement\u003c\/td\u003e\u003ctd data-r style=\"text-align:left\"\u003e\u003cstrong\u003eFinishes\u003c\/strong\u003e\u003c\/td\u003e\u003ctd data-r style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003esatin nickel or dark bronze\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr style=\"background-color:var(--wb-neutral-50);--wb-l:6;--wb-r:13;--wb-lb:transparent;--wb-rb:var(--wb-neutral-50)\"\u003e\u003ctd style=\"text-align:left\"\u003e\u003cstrong\u003eSignal-to-noise ratio (with 1 Pa at 1 kHz)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003eCCIR weighted 81 dB, A-weighted 87 dB\u003c\/td\u003e\u003ctd data-r style=\"text-align:left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\u003ctd data-r style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003e930 g\u003c\/td\u003e\u003c\/tr\u003e\n  \u003ctr style=\"background-color:transparent;--wb-l:7;--wb-r:14;--wb-lb:var(--wb-neutral-50);--wb-rb:transparent\"\u003e\u003ctd style=\"text-align:left\"\u003e\u003cstrong\u003eMaximum SPL for 0.5% THD\u003c\/strong\u003e\u003c\/td\u003e\u003ctd style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003e142 dB\u003c\/td\u003e\u003ctd data-r style=\"text-align:left\"\u003e\u003cstrong\u003eDimensions (L x ?)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd data-r style=\"text-align:left;font-weight:var(--font-body-weight-bolder)\"\u003e158 mm x 65 mm\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Microtech Gefell","offers":[{"title":"Default Title","offer_id":54357115994387,"sku":"214163","price":5274.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/0872\/6803\/files\/a9829a7a9cf42c911d24bfbb81b58a7226ac91b2_MICROTECHGEFELL_UM930SCT_FULL_BRONZE.jpg?v=1789348127","url":"https:\/\/woodbrass.shop\/products\/microtech-gefell-um930-full-bronze-214163","provider":"Woodbrass.com","version":"1.0","type":"link"}